Show simple item record

dc.contributor.authorYılmaz, Gizem
dc.contributor.authorYeşil, Zeynep
dc.date.accessioned2025-06-12T06:57:18Z
dc.date.available2025-06-12T06:57:18Z
dc.date.issued2025en_US
dc.identifier.citationYılmaz, G., & Yeşil, Z. (2025). A new era in provisional restorations: evaluating marginal accuracy and fracture strength in additive, substractive and conventional techniques. BMC oral health, 25(1), 909. https://doi.org/10.1186/s12903-025-06296-5en_US
dc.identifier.issn1472-6831
dc.identifier.urihttps://doi.org/10.1186/s12903-025-06296-5
dc.identifier.urihttps://hdl.handle.net/11436/10380
dc.description.abstractObjective: The aim of this study was to compare the marginal gaps and fracture resistance of fixed provisional restorations fabricated using conventional, subtractive (Computer-Aided Design/Computer-Aided Manufacturing (CAD/CAM)), and additive (3D printing) techniques. Materials and methods: In this study, fixed provisional restorations were fabricated on 60 epoxy resin dies using conventional, subtractive, and additive methods. The marginal gaps of the restorations cemented onto epoxy resin dies with temporary cement were measured using a stereomicroscope. Half of the samples from each group were stored in artificial saliva at 37 °C, while the other half underwent 5000 thermal cycles for aging. After the aging process, marginal gap measurements were repeated using a stereomicroscope. Scanning Electron Microscope (SEM) images were obtained for one sample from each group prepared using different techniques, with and without the aging process. Fracture resistance was evaluated using an Instron Universal Testing Machine. The data were analyzed using the Jamovi statistical software (version 2.3.28) with two-way analysis of variance and Tukey’s post hoc test. Results: Variance analysis revealed that the fabrication method and aging process significantly affected the results (p < 0.05). There was no significant difference in the marginal gaps of restorations fabricated using subtractive and additive techniques (p > 0.05). However, restorations fabricated using subtractive and additive methods exhibited significantly smaller marginal gaps compared to those fabricated using the conventional method (p < 0.001). In terms of fracture resistance, there was no significant difference between restorations fabricated using the additive and conventional methods (p > 0.05). However, both showed significantly lower fracture resistance compared to restorations fabricated using the subtractive method (p < 0.001). Discussion: This study determined that the highest fracture resistance was observed in restorations fabricated using the subtractive method, while the lowest was found in those fabricated using the additive method. For long-term use of fixed provisional restorations, the subtractive method (CAD/CAM) may be considered.en_US
dc.language.isoengen_US
dc.publisherBioMed Central Ltden_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectAdditive methoden_US
dc.subjectConventional methoden_US
dc.subjectFixed provisional restorationsen_US
dc.subjectFracture resistanceen_US
dc.subjectMarginal gapen_US
dc.subjectSubtractive methoden_US
dc.titleA new era in provisional restorations: evaluating marginal accuracy and fracture strength in additive, substractive and conventional techniquesen_US
dc.typearticleen_US
dc.contributor.departmentRTEÜ, Diş Hekimliği Fakültesi, Klinik Bilimler Bölümüen_US
dc.contributor.institutionauthorYılmaz, Gizem
dc.contributor.institutionauthorYeşil, Zeynep
dc.identifier.doi10.1186/s12903-025-06296-5en_US
dc.identifier.volume25en_US
dc.identifier.issue1en_US
dc.identifier.startpage909en_US
dc.relation.journalBMC Oral Healthen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Files in this item

This item appears in the following Collection(s)

Show simple item record