• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   RTEÜ
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
  •   RTEÜ
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

A comparison of two methods used for determination of tritium concentration in urine samples by liquid scintillation counter

Thumbnail

Göster/Aç

Full Text / Tam Metin (456.6Kb)

Erişim

info:eu-repo/semantics/closedAccess

Tarih

2018

Yazar

Dizman, Serdar
Keser, Recep

Üst veri

Tüm öğe kaydını göster

Künye

Dizman, S. & Keser, R. (2018). A comparison of two methods used for determination of tritium concentration in urine samples by liquid scintillation counter. Radiation Detection Technology and Methods, 2(1), 23. https://doi.org/10.1007/s41605-018-0056-0

Özet

Background Tritium (3H) emits low-energy beta particles with a maximum energy of 18.6 keV. Liquid scintillation counting technique (LSC) is mostly used for the detection and quantification of low-energy emitters like H-3. the most widely used method to determine the level of tritium in humans is testing urine. Method in this study, tritium activity concentrations in urine samples taken from 20 adults were measured. Their ages range from 23 to 50. Eight of them are female, and others are male. the tritium activity concentrations in urine samples were determined with two different methods. Also, two standard samples were used to compare urine samples. Result the efficiency values were found with two different methods (26.07% for the first method and 26.14% for the second method). According to the comparison results, the tritium concentration differences between these methods were found in a negligible level for urine samples and in an acceptable level for standard samples. Conclusion the tritium activity concentrations in urine and standard samples were calculated using two different methods. According to the comparison results, these two methods can be used for determination of tritium concentrations in urine samples.

Kaynak

Radiation Detection Technology and Methods

Cilt

2

Sayı

1

Bağlantı

https://doi.org/10.1007/s41605-018-0056-0
https://hdl.handle.net/11436/1823

Koleksiyonlar

  • FEF, Fizik Bölümü Koleksiyonu [355]
  • Scopus İndeksli Yayınlar Koleksiyonu [5931]
  • WoS İndeksli Yayınlar Koleksiyonu [5260]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Yönerge | Rehber | İletişim |

DSpace@RTEÜ

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

İstatistikler

Google Analitik İstatistiklerini Görüntüle

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Rehber|| Yönerge || Kütüphane || Recep Tayyip Erdoğan Üniversitesi || OAI-PMH ||

Recep Tayyip Erdoğan Üniversitesi, Rize, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Recep Tayyip Erdoğan Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@RTEÜ:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.