Basit öğe kaydını göster

dc.contributor.authorGüngör, Hasan
dc.contributor.authorGündoğdu, Mustafa
dc.contributor.authorAlkurt, Murat
dc.contributor.authorYeşil Duymuş, Zeynep
dc.date.accessioned2020-12-19T19:48:45Z
dc.date.available2020-12-19T19:48:45Z
dc.date.issued2017
dc.identifier.citationGungor, H., Gundogdu, M., Alkurt, M., & Yesil Duymus, Z. (2017). Effect of polymerization cycles on flexural strengths and microhardness of different denture base materials. Dental materials journal, 36(2), 168–173. https://doi.org/10.4012/dmj.2016-023en_US
dc.identifier.issn0287-4547
dc.identifier.urihttps://doi.org/10.4012/dmj.2016-023
dc.identifier.urihttps://hdl.handle.net/11436/2155
dc.descriptionGundogdu, Mustafa/0000-0003-2527-0392en_US
dc.descriptionWOS: 000402590800007en_US
dc.descriptionPubMed: 28090030en_US
dc.description.abstractThe purpose of this study was to evaluate the effect of.different polymerization cycles on the flexural strengths and microhardness of two denture base materials (Meliodent and Paladent). Heat-polymerized acrylic resin specimens (65.0 mm longx10.0 mm widex2.5 mm in height) were prepared using different short and long polymerization cycles. After the specimens had been polymerized, they were stored in distilled water at 37 +/- 1 degrees C for 24 h. Flexural strength test was performed at a cross-head speed of 5 mm/min and Vickers microhardness was measured. Data were analyzed with a 1-way analysis of variance followed by Tukey test, and Student t-test (alpha=0.05). the flexural strengths and microhardness were significantly different between Meliodent and Paladent (p<0.05). Significant differences were found among the polymerization cycles in terms of flexural strengths and microhardness (p<0.05). Polymerization with G cycle may be suggested for Meliodent and H cycle may be suggested for Paladent.en_US
dc.description.sponsorshipScientific Research Projects (Atatiirk University) [2012/70]en_US
dc.description.sponsorshipSupported by the 2012/70 numbered project of Scientific Research Projects (Atatiirk University).en_US
dc.language.isoengen_US
dc.publisherJapanese Soc Dental Materials Devicesen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectDenture base materialen_US
dc.subjectFlexural strengthen_US
dc.subjectMicrohardnessen_US
dc.subjectPolymerization cycleen_US
dc.titleEffect of polymerization cycles on flexural strengths and microhardness of different denture base materialsen_US
dc.typearticleen_US
dc.contributor.departmentRTEÜ, Diş Hekimliği Fakültesi, Klinik Bilimler Bölümüen_US
dc.contributor.institutionauthorAlkurt, Murat
dc.identifier.doi10.4012/dmj.2016-023
dc.identifier.volume36en_US
dc.identifier.issue2en_US
dc.identifier.startpage168en_US
dc.identifier.endpage173en_US
dc.ri.editoaen_US
dc.relation.journalDental Materials Journalen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster