dc.contributor.author | Güngör, Hasan | |
dc.contributor.author | Gündoğdu, Mustafa | |
dc.contributor.author | Alkurt, Murat | |
dc.contributor.author | Yeşil Duymuş, Zeynep | |
dc.date.accessioned | 2020-12-19T19:48:45Z | |
dc.date.available | 2020-12-19T19:48:45Z | |
dc.date.issued | 2017 | |
dc.identifier.citation | Gungor, H., Gundogdu, M., Alkurt, M., & Yesil Duymus, Z. (2017). Effect of polymerization cycles on flexural strengths and microhardness of different denture base materials. Dental materials journal, 36(2), 168–173. https://doi.org/10.4012/dmj.2016-023 | en_US |
dc.identifier.issn | 0287-4547 | |
dc.identifier.uri | https://doi.org/10.4012/dmj.2016-023 | |
dc.identifier.uri | https://hdl.handle.net/11436/2155 | |
dc.description | Gundogdu, Mustafa/0000-0003-2527-0392 | en_US |
dc.description | WOS: 000402590800007 | en_US |
dc.description | PubMed: 28090030 | en_US |
dc.description.abstract | The purpose of this study was to evaluate the effect of.different polymerization cycles on the flexural strengths and microhardness of two denture base materials (Meliodent and Paladent). Heat-polymerized acrylic resin specimens (65.0 mm longx10.0 mm widex2.5 mm in height) were prepared using different short and long polymerization cycles. After the specimens had been polymerized, they were stored in distilled water at 37 +/- 1 degrees C for 24 h. Flexural strength test was performed at a cross-head speed of 5 mm/min and Vickers microhardness was measured. Data were analyzed with a 1-way analysis of variance followed by Tukey test, and Student t-test (alpha=0.05). the flexural strengths and microhardness were significantly different between Meliodent and Paladent (p<0.05). Significant differences were found among the polymerization cycles in terms of flexural strengths and microhardness (p<0.05). Polymerization with G cycle may be suggested for Meliodent and H cycle may be suggested for Paladent. | en_US |
dc.description.sponsorship | Scientific Research Projects (Atatiirk University) [2012/70] | en_US |
dc.description.sponsorship | Supported by the 2012/70 numbered project of Scientific Research Projects (Atatiirk University). | en_US |
dc.language.iso | eng | en_US |
dc.publisher | Japanese Soc Dental Materials Devices | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Denture base material | en_US |
dc.subject | Flexural strength | en_US |
dc.subject | Microhardness | en_US |
dc.subject | Polymerization cycle | en_US |
dc.title | Effect of polymerization cycles on flexural strengths and microhardness of different denture base materials | en_US |
dc.type | article | en_US |
dc.contributor.department | RTEÜ, Diş Hekimliği Fakültesi, Klinik Bilimler Bölümü | en_US |
dc.contributor.institutionauthor | Alkurt, Murat | |
dc.identifier.doi | 10.4012/dmj.2016-023 | |
dc.identifier.volume | 36 | en_US |
dc.identifier.issue | 2 | en_US |
dc.identifier.startpage | 168 | en_US |
dc.identifier.endpage | 173 | en_US |
dc.ri.edit | oa | en_US |
dc.relation.journal | Dental Materials Journal | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |