dc.contributor.author | Terzi, Suat | |
dc.contributor.author | Dursun, Engin | |
dc.contributor.author | Özgür, Abdulkadir | |
dc.contributor.author | Coşkun, Zerrin Özergin | |
dc.contributor.author | Erdivanlı, Özlem Çelebi | |
dc.contributor.author | Birinci, Mehmet | |
dc.contributor.author | Demirci, Münir | |
dc.date.accessioned | 2020-12-19T19:50:40Z | |
dc.date.available | 2020-12-19T19:50:40Z | |
dc.date.issued | 2016 | |
dc.identifier.citation | Terzi, S., Dursun, E., Ozgur, A., Coskun, Z.O., Erdivanli, O.C., Ozlem, C., Birinci, M., Demirci, M. (2016). Can use of a cold light source in endoscopic middle ear surgery cause sensorineural hearing loss?. Indian Journal of Otology, 22(3), 213-216. https://doi.org/10.4103/0971-7749.187982 | en_US |
dc.identifier.issn | 0971-7749 | |
dc.identifier.issn | 2249-9520 | |
dc.identifier.uri | https://doi.org/10.4103/0971-7749.187982 | |
dc.identifier.uri | https://hdl.handle.net/11436/2455 | |
dc.description | WOS: 000387945900015 | en_US |
dc.description.abstract | Objectives: To investigate possible sensorineural hearing loss created by the use of a cold light source in patients undergoing endoscopic tympanoplasty surgery. Materials and Methods: the medical records of 203 patients, who underwent endoscopic Type 1 tympanoplasty surgery in our ear, nose, and throat clinic between 2012 and 2015, were checked retrospectively. Ninety-one patients were male and 112 were female, and their mean age was 34.4 +/- 11.2 years. Results of audiometric measurements performed during the preoperative period and repeated 1 and 3 months postsurgery were compared to each other. Results: the mean duration of the operations was determined to be 52.4 +/- 9.1 min. in addition, average preoperative bone-conduction was 11.4 +/- 7.4 dB nHL. However, it was 9.57 +/- 7.1 dB nHL and 9.51 +/- 7.4 dB nHL, respectively, in the 1st and 3rd postoperative months. Levels of postoperative average bone-conduction at the 1st and 3rd month, as well as the thresholds of bone-conduction at 500, 1000, and 2000 Hz, were significantly lower than the preoperative results (P < 0.05). However, there was not a remarkable difference at 4000 Hz (P > 0.05). Conclusion: Based on our findings, the increased heat generated by the use of a cold light source during an endoscopic tympanoplasty surgery is unlikely to cause the development of sensorineural hearing loss. | en_US |
dc.language.iso | eng | en_US |
dc.publisher | Medknow Publications & Media Pvt Ltd | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Audiological surgical procedures | en_US |
dc.subject | Cold light sources | en_US |
dc.subject | Tympanoplasty | en_US |
dc.title | Can use of a cold light source in endoscopic middle ear surgery cause sensorineural hearing loss? | en_US |
dc.type | article | en_US |
dc.contributor.department | RTEÜ, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü | en_US |
dc.contributor.institutionauthor | Terzi, Suat | |
dc.contributor.institutionauthor | Dursun, Engin | |
dc.contributor.institutionauthor | Özgür, Abdulkadir | |
dc.contributor.institutionauthor | Coşkun, Zerrin Özergin | |
dc.contributor.institutionauthor | Erdivanlı, Özlem Çelebi | |
dc.contributor.institutionauthor | Birinci, Mehmet | |
dc.contributor.institutionauthor | Demirci, Münir | |
dc.identifier.doi | 10.4103/0971-7749.187982 | |
dc.identifier.volume | 22 | en_US |
dc.identifier.issue | 3 | en_US |
dc.identifier.startpage | 213 | en_US |
dc.identifier.endpage | 216 | en_US |
dc.relation.journal | Indian Journal of Otology | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |