Artifact expression of polyetheretherketone in cone beam computed tomography: An in vitro study

Thumbnail

Göster/Aç

Full Text / Tam Metin (355.1Kb)

Erişim

info:eu-repo/semantics/closedAccess

Tarih

2021

Yazar

Köse, Taha Emre
Günaçar, Dilara Nil
Ateş, Sabit Melih
Çağlar, İpek

Üst veri

Tüm öğe kaydını göster

Künye

Köse, T. E., Günaçar, D. N., Ateş, S. M., & Çağlar, İ. (2021). Artifact expression of polyetheretherketone in cone beam computed tomography: An in vitro study. The Journal of prosthetic dentistry, 126(6), 793.e1–793.e5. https://doi.org/10.1016/j.prosdent.2021.09.028

Özet

Statement of problem. Dental prosthetic materials can cause artifacts in cone beam computed tomography (CBCT) images, adversely affecting diagnostic quality, although the problem may be less with polyetheretherketone (PEEK). Studies evaluating the artifacts caused by frequently used prosthetic materials are lacking. Purpose. The purpose of this in vitro study was to compare the artifacts in CBCT images caused by PEEK, zirconia, cobalt-chromium (Co-Cr) alloy, and titanium (Ti). Material and methods. A polymethylmethacrylate phantom (empty set4.0x4.0 cm) with a central cylindrical aperture (empty set0.5x0.5 cm) was produced. Co-Cr, Ti, zirconia, and PEEK cylinders (0.5x0.5 cm) were manufactured, and CBCT images of the empty phantom (control group) with the test cylinders inside were made 3 times. In all images, the axial sections passing through the middle of the materials were evaluated. Eight regions of interest (ROI) area were determined around the materials (0.5x0.5 cm). The presence of artifacts was evaluated by making gray value standard deviation (SD) calculations in these ROI areas. The average SD values of 8 ROI fields from the 3 CBCT scans were made, and the materials were compared with each other in terms of the presence of artifacts by using 1-way analysis of variance (alpha=.05). Results. The difference between the SD values of the control and the PEEK cylinder was not statistically significant (P>.05). The SD values of both the control and PEEK groups were significantly lower than those of the zirconia, Co-Cr, and Ti groups (P<.05). Conclusions. Zirconia, Ti, and Co-Cr caused artifacts in CBCT images, but the artifacts with PEEK were similar to those in the control group, suggesting it was the optimal choice in terms of achieving diagnostic quality.

Kaynak

The Journal of Prosthetic Dentistry

Cilt

126

Sayı

6

Bağlantı

https://doi.org/10.1016/j.prosdent.2021.09.028
https://hdl.handle.net/11436/6557

Koleksiyonlar

  • DŞHF, Klinik Bilimler Bölümü Koleksiyonu [244]
  • PubMed İndeksli Yayınlar Koleksiyonu [2443]
  • Scopus İndeksli Yayınlar Koleksiyonu [5931]
  • WoS İndeksli Yayınlar Koleksiyonu [5260]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Yönerge | Rehber | İletişim |

DSpace@RTEÜ

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

İstatistikler

Google Analitik İstatistiklerini Görüntüle

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Rehber|| Yönerge || Kütüphane || Recep Tayyip Erdoğan Üniversitesi || OAI-PMH ||

Recep Tayyip Erdoğan Üniversitesi, Rize, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Recep Tayyip Erdoğan Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@RTEÜ:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.