Basit öğe kaydını göster

dc.contributor.authorÖzad, Merve Babacan
dc.contributor.authorÇıkman, Ahter Şanal
dc.contributor.authorKöse, Taha Emre
dc.contributor.authorArıcıoğlu, Banu
dc.date.accessioned2023-08-22T08:42:41Z
dc.date.available2023-08-22T08:42:41Z
dc.date.issued2023en_US
dc.identifier.citationÖzad, M.B., Çıkman, A.Ş., Köse, T.E. & Arıcıoğlu, B. (2023). Transportation and shaping ability of 3 canal anatomy-friendly systems in curved root canals. Annals of Clinical and Analytical Medicine, 14(7), 595-599. http://doi.org/10.4328/ACAM.21659en_US
dc.identifier.issn2667-663X
dc.identifier.urihttp://doi.org/10.4328/ACAM.21659
dc.identifier.urihttps://hdl.handle.net/11436/8103
dc.description.abstractAim: In this study, we aimed to compare the shaping efficacy of the TruNatomy (TRN), XP-endo Shaper (XPS), and 2Shape (TS) NiTi rotary systems in terms of canal transportation, centering ratio, and removed dentin volume using cone beam computed tomography (CBCT).Material and Methods: Sixty mesial root canals of mandibular first molar teeth with a curvature angle of 20-40 & DEG; and curvature radius of 4-6 mm were allocated to three groups (n=20). Instrumentation was performed in compliance with the manufacturer's instructions. CBCT images were taken in the same position before and after instrumentation. Canal transportation and the centering ratio were calculated at 3, 6, and 9-mm distances from the apex. Data were statistically analyzed.Results: TS group had significantly higher transportation (P<0.05) and there was no significant difference between the TRN and XPS groups. In terms of centering ability, no significant difference was detected between the groups (P>0.05). The volume of removed dentin was significantly lower in the TRN group (P<0.05) and there was no significant difference between the XPS and TS groups. Discussion: XPS and TRN groups showed less transportation than TS, whereas the centering ability was similar for all groups. In addition, the TRN group removed significantly less dentine, supporting the minimally invasive endodontic approach.en_US
dc.language.isoengen_US
dc.publisherBayrakol Medical Publisheren_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectCentering ratioen_US
dc.subjectCone-beam computed tomographyen_US
dc.subjectRoot canal volumeen_US
dc.subjectTransportationen_US
dc.subjectTruNatomyen_US
dc.titleTransportation and shaping ability of 3 canal anatomy-friendly systems in curved root canalsen_US
dc.typearticleen_US
dc.contributor.departmentRTEÜ, Diş Hekimliği Fakültesi, Klinik Bilimler Bölümüen_US
dc.contributor.institutionauthorÖzad, Merve Babacan
dc.contributor.institutionauthorÇıkman, Ahter Şanal
dc.contributor.institutionauthorKöse, Taha Emre
dc.identifier.doi10.4328/ACAM.21659en_US
dc.identifier.volume14en_US
dc.identifier.issue7en_US
dc.identifier.startpage595en_US
dc.identifier.endpage599en_US
dc.relation.journalAnnals of Clinical and Analytical Medicineen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster