Basit öğe kaydını göster

dc.contributor.authorÖzkoç, Mustafa
dc.contributor.authorAksakal, Emrah
dc.contributor.authorDerman, Ömer Faruk
dc.contributor.authorSaraç, İbrahim
dc.contributor.authorKoza, Yavuzer
dc.date.accessioned2023-08-28T12:49:32Z
dc.date.available2023-08-28T12:49:32Z
dc.date.issued2023en_US
dc.identifier.citationÖzkoç, M., Aksakal, E., Derman, Ö. F., Saraç, I., & Koza, Y. (2023). Predictive value of cardiovascular risk scoring systems for the detection of myocardial injury following carbon monoxide intoxication. Turkish journal of emergency medicine, 23(1), 30–37. https://doi.org/10.4103/2452-2473.366483en_US
dc.identifier.issn2452-2473
dc.identifier.urihttps://doi.org/10.4103/2452-2473.366483
dc.identifier.urihttps://hdl.handle.net/11436/8172
dc.description.abstractOBJECTIVES: This single-center, retrospective study investigates the predictive value of cardiovascular (CV) risk-calculation systems in patients admitted to the emergency department with carbon monoxide (CO) intoxication for the identification of potential myocardial injury.METHODS: The total CV risk of 558 patients presenting to the emergency department with CO intoxication were calculated on admission using different CV risk scoring systems, including SCORE Turkey, European Heart SCORE, and FRAMINGHAM to predict potential myocardial injury secondary to poisoning, and the risk levels were categorized based on the calculated scores. The presence of myocardial injury was identified based on the level of elevation of a cardiac biomarker (Serum cardiac troponin-I >99(th) percentile upper reference limit).RESULTS: Myocardial injury due to CO intoxication was detected in 132 (23.7%) of the patients. A comparison of the risk scoring systems' ability to detect the presence of myocardial injury revealed that all had significant, similar, but low predictive values (the "area under the curve" values of SCORE Turkey, European Heart SCORE and FRAMINGHAM were 0.653, 0.632, and 0.629, respectively; P < 0.001). Among the three risk scoring systems, SCORE Turkey was the most successful test in diagnosing myocardial injury with 87% specificity, while FRAMINGHAM scoring was the most successful test in excluding the presence of myocardial injury with 72.1% sensitivity.CONCLUSION: Among the tested CV risk-calculation systems SCORE Turkey, was found to be the most effective in the prediction of myocardial injury secondary to CO poisoning, but all produced similar and significant results.en_US
dc.language.isoengen_US
dc.publisherWolters Kluwer Medknow Publicationsen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectCarbon monoxide poisoningen_US
dc.subjectCardiotoxicityen_US
dc.subjectCardiovascular risken_US
dc.subjectMyocardial injuryen_US
dc.titlePredictive value of cardiovascular risk scoring systems for the detection of myocardial injury following carbon monoxide intoxicationen_US
dc.typearticleen_US
dc.contributor.departmentRTEÜ, İlahiyat Fakültesi, Felsefe ve Din Bilimleri Bölümüen_US
dc.contributor.institutionauthorDerman, Ömer Faruk
dc.identifier.doi10.4103/2452-2473.366483en_US
dc.identifier.volume23en_US
dc.identifier.issue1en_US
dc.identifier.startpage30en_US
dc.identifier.endpage37en_US
dc.relation.journalTurkish Journal of Emergency Medicineen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster