Geleneksel konutların restorasyon sürecinde enerji etkin iyileştirilmesi: Trabzon evi örneği

Thumbnail

Göster/Aç

Full Text / Tam Metin (1.388Mb)

Erişim

info:eu-repo/semantics/openAccess

Tarih

2023

Yazar

Lakot Alemdağ, Esra
Şahin, Birol
Akkan Çavdar, Ayça

Üst veri

Tüm öğe kaydını göster

Künye

Lakot Alemdağ, E., Şahin, B. & Akkan, A. (2023). Geleneksel Konutların Restorasyon Sürecinde Enerji Etkin İyileştirilmesi: Trabzon Evi Örneği. Karadeniz Fen Bilimleri Dergisi, 13(), 202-222. https://doi.org/10.31466/kfbd.1229963

Özet

İnşaat sektörü küresel enerji kullanımında ve çevresel sorunlarda önemli bir paya sahiptir. Konutlarda enerji verimliliğini arttıracak önlemler ile iç mekân iklimsel konforu iyileştirilerek daha az enerji tüketen, sürdürülebilir yapılı çevreler oluşturmak mümkündür. Ülkemizdeki konut stoğu düşünüldüğünde mevcut yapılarda yapılacak enerji etkin iyileştirmeler, verimlilik açısından düşük enerjili yeni bir bina inşa etmek kadar etkili olacaktır. Kentlerin kimliğini yansıtan tescilli geleneksel konutlar da mevcut yapı stoğunun önemli bir parçasıdır. Bu yapıların taşıdığı kültürel değerlerin korunmasının yanı sıra enerji performanslarının da iyileştirilmesi gerekmektedir. Yapılan çalışmada Trabzon ilinde yer alan restore edilmiş tescilli konutlardan biri seçilerek yapı dış kabuğu ve döşemeleri için enerji etkin iyileştirme önerileri hazırlanmıştır. Binanın ısı yalıtım performansının arttırılması ve farklı yalıtım malzemelerinin etkinliğinin incelenmesi amacıyla hazırlanan bu öneriler TSE 825 Hesap programı kullanılarak irdelenmiştir. Binanın zemin ve 1. katında yer alan her bir mekân için ısı kayıpları hesaplanmıştır. Ayrıca çalışmada önerilen dış duvar alternatifleri için aynı programda yoğuşma kontrolü de yapılmıştır. Sonuç olarak bağdadi duvar yapım sistemine sahip binada uygulanan yalıtım önerileri yıllık ısıtma yüklerinde % 66.8 ile % 68.8 arasında azalma sağlamıştır. Isıtma yükünün en fazla olduğu Ocak ayında örnek binada maksimum %66.4 tasarruf sağlanmıştır. Bu uygulamalar sonucunda duvar konstrüksiyonlarında herhangi bir yoğuşma problemi de meydana gelmemiştir.
 
The construction industry has a significant share in global energy use and environmental problems. It is possible to create sustainable built environments that consume less energy by improving indoor climatic comfort with measures to increase energy efficiency in houses. Considering the housing stock in our country, energy efficient improvements to be made in existing buildings will be as effective as constructing a new low-energy building in terms of efficiency. Registered traditional residences reflecting the identity of cities are also an important part of the existing building stock. In addition to preserving the cultural values of these structures, their energy performance should also be improved. In the study, one of the restored registered houses in the province of Trabzon was selected and energy efficient improvement suggestions were prepared for the outer skin and flooring of the building. These suggestions, which were prepared to increase the thermal insulation performance of the building and to examine the effectiveness of different insulation materials, were examined using the TSE 825 Calculation program. Heat losses were calculated for each space on the ground and first floor of the building. In addition, condensation control was carried out in the same program for the exterior wall alternatives in the study. As a result, insulation recommendations applied in the building with the bağdadi wall construction system have reduced the annual heating loads between 66.8 % and 68.8 %. In January, when the heating load was the highest, a max. of 66.4% savings was achieved in the sample building. As a result of these applications, no condensation problem has occurred in the wall constructions.
 

Kaynak

Karadeniz Fen Bilimleri Dergisi

Cilt

13

Sayı

1

Bağlantı

https://doi.org/10.31466/kfbd.1229963
https://hdl.handle.net/11436/8498

Koleksiyonlar

  • Mimarlık Bölümü Koleksiyonu [82]
  • TR-Dizin İndeksli Yayınlar Koleksiyonu [2844]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Yönerge | Rehber | İletişim |

DSpace@RTEÜ

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

İstatistikler

Google Analitik İstatistiklerini Görüntüle

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Rehber|| Yönerge || Kütüphane || Recep Tayyip Erdoğan Üniversitesi || OAI-PMH ||

Recep Tayyip Erdoğan Üniversitesi, Rize, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Recep Tayyip Erdoğan Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@RTEÜ:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.