• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   RTEÜ
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • TR-Dizin İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
  •   RTEÜ
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • TR-Dizin İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Strength of connection profiles used in cross-laminated timber walls under seismic load

Thumbnail

Göster/Aç

Full Text / Tam Metin (1.002Mb)

Erişim

info:eu-repo/semantics/closedAccess

Tarih

2023

Yazar

Tandoğan Kibar, Gülten
Lakot Alemdağ, Esra

Üst veri

Tüm öğe kaydını göster

Künye

Tandoğan Kibar, G. & Lakot Alemdağ, E. (2023). Strength of connection profiles used in cross-laminated timber walls under seismic load. Journal of Structural Engineering & Applied Mechanics, 6(1), 45-59. http://doi.org/10.31462/jseam.2023.01045059

Özet

Cross-laminated wood (CLT) material, which has many advantages, has been widely used in architectural designs as a building element and building material in recent years. It has been proven that CLT can also show high performance against ground vibrations, but it is also mentioned in the literature that some problems such as rupture, snagging, and breaking occur in the elements used in the connections of the walls to the floor and the ground. This study was conducted to examine the performance of fasteners used in CLT walls against lateral load. In this context, 4 CLT walls were produced and then 5 metal profiles were designed to be used in the connection of these walls with the foundation ground. CLT wall and connection profiles, created according to ASTM E 72 standards, have been tested in an experimental setup with different detail options. According to the test results, it was observed that some of the CLT walls and connection profiles showed high performance at maximum load, displacement, and stiffness values. As a result, it has been determined that the resistance of the CLT material against lateral earthquake load can be increased with the right fasteners, and the collapse time of the structure in the event of an earthquake can be indirectly extended.

Kaynak

Journal of Structural Engineering & Applied Mechanics

Cilt

6

Sayı

1

Bağlantı

http://doi.org/10.31462/jseam.2023.01045059
https://hdl.handle.net/11436/8500

Koleksiyonlar

  • Mimarlık Bölümü Koleksiyonu [82]
  • TR-Dizin İndeksli Yayınlar Koleksiyonu [2844]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Yönerge | Rehber | İletişim |

DSpace@RTEÜ

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

İstatistikler

Google Analitik İstatistiklerini Görüntüle

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Rehber|| Yönerge || Kütüphane || Recep Tayyip Erdoğan Üniversitesi || OAI-PMH ||

Recep Tayyip Erdoğan Üniversitesi, Rize, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Recep Tayyip Erdoğan Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@RTEÜ:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.