Basit öğe kaydını göster

dc.contributor.authorGonca, Merve
dc.contributor.authorTurgut, Çiğdem Sazak
dc.contributor.authorGündoğdu, Şeyma
dc.date.accessioned2024-11-04T07:58:03Z
dc.date.available2024-11-04T07:58:03Z
dc.date.issued2024en_US
dc.identifier.citationGonca, M., Sazak, Ç., & Gündoğdu, Ş. (2024). Effects of Contrast Limited Adaptive Histogram Equalization (CLAHE) on Manual and Automated Tracing of Lateral Cephalometric Radiographs. Clinical and Experimental Health Sciences, 14(3), 733-744. https://doi.org/10.33808/clinexphealthsci.1357008en_US
dc.identifier.isbn2459-1459
dc.identifier.urihttps://doi.org/10.33808/clinexphealthsci.1357008
dc.identifier.urihttps://hdl.handle.net/11436/9692
dc.description.abstractObjective: The aim of this study is to compare the difference between original lateral cephalometric radiographs (LCRs) and Contrast Limited Adaptive Histogram Equalization (CLAHE) LCRs in two examiners and WebCeph. Methods: A total of 200 LCRs were selected, and CLAHE (tile size: 20*20) was applied to the original LCRs. 27 LCR landmarks were manually determined by two examiners and, the selected LCR's determined automatically using the WebCeph program. Absolute differences between the original LCRs and CLAHE-LCRs were calculated in the x-y axes and Euclidean distance. The Kruskal Wallis test was used for comparisons between the examiners and WebCeph. The Wilcoxon Signed Rank Test was used to evaluate the x and y axes within each group. Results: The best accuracy values were seen in examiner 1 along the x-y axes and Euclidean distance, while the worst accuracy values were seen in WebCeph. The mean differences according to the methods were higher along the y-axis than along the x-axis for both examiners (except PNS, Me') and WebCeph (except Po, Co). The mean Euclidean distances were above 2 mm only in Co, PNS at Examiner 1, PNS, Po, Ba, Co, Go, Pog, U1RT, Me', Pog at Examiner 2, and WebCeph in all measurements. However, the differences in Euclidean distances were less than 4 mm for both examiners and WebCeph. Conclusion: CLAHE-LCRs require more adjustments for landmark determination in WebCeph than the in the manual system.en_US
dc.language.isoengen_US
dc.publisherMarmara Üniversitesien_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectOrthodonticsen_US
dc.subjectRadiographyen_US
dc.subjectCephalometryen_US
dc.subjectImage enhancementen_US
dc.subjectArtificial intelligenceen_US
dc.subjectDiagnostic imagingen_US
dc.titleEffects of contrast limited adaptive histogram equalization (CLAHE) on manual and automated tracing of lateral cephalometric radiographsen_US
dc.typearticleen_US
dc.contributor.departmentRTEÜ, Diş Hekimliği Fakültesi, Klinik Bilimler Bölümüen_US
dc.contributor.institutionauthorGonca, Merve
dc.contributor.institutionauthorTurgut, Çiğdem Sazak
dc.identifier.doi10.33808/clinexphealthsci.1357008en_US
dc.identifier.volume14en_US
dc.identifier.issue3en_US
dc.identifier.startpage733en_US
dc.identifier.endpage744en_US
dc.relation.journalClinical and Experimental Health Sciencesen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster