Biomechanical evaluation of six zygomatic implants versus four zygomatic implants combined with dental implants in the treatment of different maxillary defects
Citation
Gümrükçü, Z., Balaban, E., & Bayramoğlu, Z. (2024). Biomechanical evaluation of six zygomatic implants versus four zygomatic implants combined with dental implants in the treatment of different maxillary defects. BMC Oral Health, 24(1), 1230. https://doi.org/10.1186/s12903-024-05031-wAbstract
Background: This study aims to compare the biomechanics of six zygomatic implants (ZIs) and dental implants (DIs) combined with four ZIs with different maxilla defects. Methods: Three-dimensional constructs of the ZIs, DIs human skulls, and maxillary prostheses were created using SolidWorks Software (Version 2015, Dassault Systems SolidWorks Corporation, Waltham, MA, USA). Eight finite element models of the skull with four different alveolar defect types (0–4) were constructed. Type 0: No defect; Type 1: Bilateral posterior defects; Type 2: Right posterior defect; Type 3: Anterior and left posterior defects; Type 4: Bilateral posterior and anterior defects. In two models with the same defect type (for defect types 0–2), six ZIs or two DIs combined with four ZIs were inserted into the maxilla. Six ZIs were inserted in the maxilla models with defect types 3 and 4. Vertical (150 N) and masseteric (300 N) loads were simulated on the prosthesis. The maximum Von Mises stress in the implants/surrounding bone and bone deformation were evaluated. Results: The maximum Von Mises stresses in bone/implant were found highest in the defect type 2 model with four ZIs combined with two DIs. The lowest maximum Von Mises stress for bone was detected in the model with defect type 0 and with six ZIs. Conclusion: Among the four types of defects, the posterior unilateral defect caused the highest stress value.
Source
BMC Oral HealthVolume
24Issue
1Collections
Related items
Showing items related by title, author, creator and subject.
-
Relation of multicenter automatic defibrillator implantation trial implantable cardioverter-defibrillator score with long-term cardiovascular events in patients with implantable cardioverter-defibrillator
Uslu, Abdulkadir; Doğan, Cem; Duman, Hakan; Tanboğa, İbrahim Halil; Aşkın, Lütfü; Sevimli, Serdar (Kare PUBL, 2019)OBJECTIVE: To test the hypothesis that multicenter automatic defibrillator implantation trial (MADIT) - implantable cardioverter-defibrillator (ICD) scores predict replacement requirement and appropriate shock in a mixed ... -
İmplant destekli hareketli protezlerde kullanılan çeşitli bağlantı sistemlerine mekanik ve termal yaşlandırma işlemlerinin etkisinin incelenmesi
Yıldırım, Mustafa (Recep Tayyip Erdoğan Üniversitesi / Diş Hekimliği Fakültesi / Protetik Diş Tedavisi Anabilim Dalı, 2018)Amaç: Bu çalışma, implant destekli overdenture protezlerin çeşitli tutucu sistemlerinin retansiyonuna, mekanik yaşlandırma ve termal siklus uygulamalarının etkisini incelemek amacıyla yapıldı. Materyal ve Metod: Çalışmada ... -
Dört Farklı Tip Alveoler Defekte Sahip Maksillada Dörtlü Zigomatik İmplant Uygulamasının Biyomekanik Etkilerinin Değerlendirilmesi
Gümrükçü, Zeynep (2019)Amaç: Bu çalışmanın amacı, dört farklı alveoler defekt tipine sahip maksillada dörtlü zigomatik implant kullanımının biyomekanik etkilerini değerlendirmektir. Materyal ve Metod: SolidWorks Computer-Aided Design (CAD) ...