• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   RTEÜ
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
  •   RTEÜ
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Could the novel 'double-hole' technique be an alternative for the inflow occlusion method?

Thumbnail

Göster/Aç

Full Text / Tam Metin (9.884Mb)

Erişim

info:eu-repo/semantics/openAccess

Tarih

2016

Yazar

Bozok, Şahin
İlhan, Gökhan
Kazdal, Hızır
Özpak, Berkan
Yürekli, İsmail
Bayrak, Serdar
Kestelli, Mert

Üst veri

Tüm öğe kaydını göster

Künye

Bozok, S., Ilhan, G., Kazdal, H., Ozpak, B., Yurekli, I., Bayrak, S., & Kestelli, M. (2016). Could the novel 'double-hole' technique be an alternative for the inflow occlusion method?. Cardiovascular journal of Africa, 27(5), 291–293. https://doi.org/10.5830/CVJA-2016-020

Özet

Background: Inflow occlusion on beating heart and cardiopulmonary bypass techniques have been proposed for the removal of foreign material, such as stents, catheters and mass lesions, from cardiac chambers. However, both techniques are not devoid of disadvantages and complications. in this article, we define an alternative, novel 'double-hole' technique, which is based on opening the right atrium without cardiopulmonary bypass. Methods: Bovine hearts were obtained from a local supermarket. Two purse-string sutures were placed in the right atrium using 2-0 braided, non-absorbable polyester suture material, one close to the auricle, and the other close to the interatrial septum. the guidewire of a haemodialysis catheter was inserted through the superior vena cava into the right atrium and passed all the way through the right ventricle Results: We suggest that the double-hole technique may be useful, especially in revision cases with adhesions Further research should be performed to document the efficacy and safety of this method. Conclusion: We are aware that further extensive research is necessary to investigate the utility of this novel technique in contemporary cardiovascular surgery. We believe the double-hole technique has the potential to become a safe, practical and effective measure in the future.

Kaynak

Cardiovascular Journal of Africa

Cilt

27

Sayı

5

Bağlantı

https://doi.org/10.5830/CVJA-2016-020
https://hdl.handle.net/11436/2411

Koleksiyonlar

  • PubMed İndeksli Yayınlar Koleksiyonu [2443]
  • Scopus İndeksli Yayınlar Koleksiyonu [5990]
  • TF, Cerrahi Tıp Bilimleri Bölümü Koleksiyonu [1220]
  • WoS İndeksli Yayınlar Koleksiyonu [5260]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Yönerge | Rehber | İletişim |

DSpace@RTEÜ

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

İstatistikler

Google Analitik İstatistiklerini Görüntüle

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Rehber|| Yönerge || Kütüphane || Recep Tayyip Erdoğan Üniversitesi || OAI-PMH ||

Recep Tayyip Erdoğan Üniversitesi, Rize, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Recep Tayyip Erdoğan Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@RTEÜ:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.