Exergoenvironmental and exergoeconomic analyses of a vertical type ground source heat pump integrated wall cooling system

Thumbnail

View/Open

Full Text / Tam Metin (2.849Mb)

Access

info:eu-repo/semantics/closedAccess

Date

2016

Author

Akbulut, Uğur
Utlu, Zafer
Kincay, Olcay

Metadata

Show full item record

Citation

Akbulut, U., Utlu, Z., Kincay, O. (2016). Exergoenvironmental and exergoeconomic analyses of a vertical type ground source heat pump integrated wall cooling system. Applied Thermal Engineering, 102, 904-921. https://doi.org/10.1016/j.applthermaleng.2016.03.178

Abstract

In this study, exergoenvironmental, and exergoeconomic analyses of wall cooling systems fed by a vertical type of ground source heat pump integrated wall cooling system for cooling were examined experimentally and theoretically in Yildiz Renewable Energy House at Davutpasa Campus of Yildiz Technical University. the examination includes energy, exergy, exergoenvironmental and exergoeconomic analyses, between the dates of 1 July and 30 September 2013. the main aim of this objective is to minimize energy usage in Residential Sector as low as possible. Therefore, a particular system working with low temperature regime was chosen. According to the outcomes; energy and exergy efficiency of all the system have been found as 74.85% and 29.90%. Part-based environmental factor values are calculated. the compressor and underground heat exchanger have the highest values calculated as 0.040 mPts/s, 0.026 mPts/s respectively. the exergoenvironmental impact values of all system are detected as 42.60%. on the other hand; the exergoeconomic factor values of all system are calculated as 77.68%. the value of exergoeconomic factor changes depending on some particular components: accumulator tank, undersoil heat exchanger, evaporator and condenser calculated respectively as 69.43%, 62.59%, 62.53% and 29.15%. As a result; it is found that in order to determine economic and environmental impacts of irreversibilities occurring in the system and its components, economic and environmental analyses of thermal system as well as wall cooling systems, should be done based on exergy concept. (C) 2016 Elsevier Ltd. All rights reserved.

Source

Applied Thermal Engineering

Volume

102

URI

https://doi.org/10.1016/j.applthermaleng.2016.03.178
https://hdl.handle.net/11436/2487

Collections

  • Makine Mühendisliği Bölümü Koleksiyonu [335]
  • WoS İndeksli Yayınlar Koleksiyonu [5260]



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Instruction | Guide | Contact |

DSpace@RTEÜ

by OpenAIRE
Advanced Search

sherpa/romeo

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution AuthorThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution Author

My Account

LoginRegister

Statistics

View Google Analytics Statistics

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Guide|| Instruction || Library || Recep Tayyip Erdoğan University || OAI-PMH ||

Recep Tayyip Erdoğan University, Rize, Turkey
If you find any errors in content, please contact:

Creative Commons License
Recep Tayyip Erdoğan University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@RTEÜ:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.