Improving thermal resistance of lightweight concrete hollow bricks: A numerical optimisation research for a typical masonry unit

Göster/Aç

Tam Metin / Full Text (2.153Mb)

Erişim

info:eu-repo/semantics/openAccess

Tarih

2020

Yazar

Cüce, Erdem
Cüce, Pınar Mert
Beşir, Ahmet B.

Üst veri

Tüm öğe kaydını göster

Künye

Cüce, E., Cüce, P.M. & Beşir, A.B. (2020). Improving thermal resistance of lightweight concrete hollow bricks: A numerical optimisation research for a typical masonry unit. Journal of Energy Systems, 4(3), 121-144. https://doi.org/10.30521/jes.775961

Özet

Heat loss/gain through the walls accounts for about 30% of the total building energy losses. Bricks are indispensable parts of buildings as a very common masonry wall unit; hence the present work aims at optimising thermal resistance of lightweight concrete hollow bricks through a CFD based numerical research. The optimisation is conducted over a certain number of independent variables such as hollow geometry and design, number of hollow rows across the heat transfer path and hollow depth for natural convection aspects within the hollow enclosure. A reliable CFD software ANSYS FLUENT 18.1 is utilised in the research. The accuracy of the CFD results is justified first through the reference model brick (RMB). Overall heat transfer coefficient (U-value) of RMB is determined to be 0.916 W/m2. K, which is in good accordance with the manufacturer’s data report (0.9 W/m2.K). Following this, parametric research is carried out for various scenarios to optimise the U-value as a function of brick mass. Based on the findings, the maximum improvement is found to be about 53% (U-value 0.43 W/m2. K) through the case of B48 which has an h-ratio of 1 (continuous hollow from top to bottom). Moreover, depending on the increase in h-ratio, it is achieved that the thermal performance of the bricks proportionally increases. The minimum weight of the brick design (B45) is found to be 7.645 kg and the corresponding U-value is obtained as 0.44 W/m2. K. © 2020 Published by peer-reviewed open access scientific journal, JES at DergiPark (https://dergipark.org.tr/en/pub/jes)

Kaynak

Journal of Energy Systems

Cilt

4

Sayı

3

Bağlantı

https://doi.org/10.30521/jes.775961
https://hdl.handle.net/11436/4500

Koleksiyonlar

  • Enerji Sistemleri Mühendisliği Bölümü Koleksiyonu [117]
  • Makine Mühendisliği Bölümü Koleksiyonu [337]
  • Scopus İndeksli Yayınlar Koleksiyonu [6023]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Yönerge | Rehber | İletişim |

DSpace@RTEÜ

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

İstatistikler

Google Analitik İstatistiklerini Görüntüle

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Rehber|| Yönerge || Kütüphane || Recep Tayyip Erdoğan Üniversitesi || OAI-PMH ||

Recep Tayyip Erdoğan Üniversitesi, Rize, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Recep Tayyip Erdoğan Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@RTEÜ:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.