• Türkçe
    • English
  • English 
    • Türkçe
    • English
  • Login
View Item 
  •   RTEÜ
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • View Item
  •   RTEÜ
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Assessment of the thermo-hydraulic efficiency of an indoor-designed jet impingement solar thermal collector roughened with single discrete arc-shaped ribs

Thumbnail

View/Open

Full Text / Tam Metin (6.658Mb)

Access

info:eu-repo/semantics/openAccess

Date

2022

Author

Kumar, Raj
Cüce, Erdem
Kumar, Sushi
Thapa, Sashank
Gupta, Paras
Goel, Bhaskar
Saleel, C. Ahamed
Shaik, Saboor

Metadata

Show full item record

Citation

Kumar, R., Cuce, E., Kumar, S.,Thapa, S., Gupta, P., Goel, B., Saleel, C.A. & Shaik, S. (2022). Assessment of the Thermo-Hydraulic Efficiency of an Indoor-Designed Jet Impingement Solar Thermal Collector Roughened with Single Discrete Arc-Shaped Ribs. Sustainability, 14(6), 3527. https://doi.org/10.3390/su14063527

Abstract

This study illustrates the impact of single discrete arc-shaped ribs (SDASR)-type artificial roughness on the performance of a jet impingement solar thermal collector (JISTC). The impact of parametric variations of SDASR on the Nusselt number (Nu(sdr)), friction factor (f(sdr)), and thermohydraulic performance (eta(sdr)) is examined. The spacer length (S-sdr) of the SDASR was changed from 0 mm to 300 mm in stages of 100 mm during the experiment. The fixed parameters of the SDASR were a relative discrete distance (D-d/L-v) of 0.67, relative discrete width (g(w)/H-r) of 0.87, relative rib height (H-r/H) of 0.047, relative rib pitch (P-r/H) of 1.7, angle of an arc (alpha(sdr)) of 60 degrees, jet diameter ratio (D-j/D-hy) of 0.065, streamwise pitch ratio (X/D-hy) of 1.72, and spanwise pitch ratio (Y/D-hy) of 0.82. The Reynolds number (Re) was altered from 3000 to 19,000. The Nu(sdr) and f(sdr) of a JISTC with a roughened absorber plate was found to be enhanced by 5.25 and 5.98 times as compared to an STC without artificial roughness. The optimal findings of Nu(sdr), f(sdr), and eta(sdr) were achieved at S-sdr = 0 mm. The maximum value of the eta(sdr) obtained at S-sdr = 0 mm was 2.9.

Source

Sustainability

Volume

14

Issue

+

URI

https://doi.org/10.3390/su14063527
https://hdl.handle.net/11436/7061

Collections

  • Makine Mühendisliği Bölümü Koleksiyonu [329]
  • Scopus İndeksli Yayınlar Koleksiyonu [5931]
  • WoS İndeksli Yayınlar Koleksiyonu [5260]



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Instruction | Guide | Contact |

DSpace@RTEÜ

by OpenAIRE
Advanced Search

sherpa/romeo

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution AuthorThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution Author

My Account

LoginRegister

Statistics

View Google Analytics Statistics

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Guide|| Instruction || Library || Recep Tayyip Erdoğan University || OAI-PMH ||

Recep Tayyip Erdoğan University, Rize, Turkey
If you find any errors in content, please contact:

Creative Commons License
Recep Tayyip Erdoğan University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@RTEÜ:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.