• Türkçe
    • English
  • English 
    • Türkçe
    • English
  • Login
View Item 
  •   RTEÜ
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • Scopus İndeksli Yayınlar Koleksiyonu
  • View Item
  •   RTEÜ
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • Scopus İndeksli Yayınlar Koleksiyonu
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Computed tomography attenuation in differential diagnosis of transudative and exudative pleural effusions

View/Open

Tam Metin / Full Text (806.5Kb)

Access

info:eu-repo/semantics/openAccess

Date

2024

Author

Gümüş, Aziz
Özçelik, Neslihan
Yılmaz Kara, Bilge
Hürsoy, Nur
Zırıh, Neşe Merve Güner
Özyurt, Songül
Şahin, Ünal

Metadata

Show full item record

Citation

Gümüş, A., Özçelik, N., Yılmaz Kara, B., Hürsoy, N., Zırıh, N. M. G., Özyurt, S., & Şahin, Ü. (2024). Computed tomography attenuation in differential diagnosis of transudative and exudative pleural effusions. Clinics (Sao Paulo, Brazil), 79, 100463. https://doi.org/10.1016/j.clinsp.2024.100463

Abstract

Objective: Pleural effusion is a common medical problem. It is important to decide whether the pleural fluid is a transudate or an exudate. This study aims to measure the attenuation values of pleural effusions on thorax computed tomography and to investigate the efficacy of this measurement in the diagnostic separation of transudates and exudates. Materials and methods: 380 cases who underwent thoracentesis and thorax computed tomography with pleural effusion were classified as exudates or transudates based on Light's criteria. Attenuation measurements in Hounsfield units were performed through the examination of thorax computed tomography images. Results: 380 patients were enrolled (39 % women), the mean age was 69.9 ± 15.2 years. 125 (33 %) were transudates whereas 255 (67 %) were exudates. The attenuation values of exudates were significantly higher than transudates (15.1 ± 5.1 and 5.0 ± 3.4) (p < 0.001). When the attenuation cut-off was set at ≥ 10 HU, exudates were differentiated from transudates at high efficiency (sensitivity is 89.7 %, specificity is 94.4 %, PPV is 97 %, NPV is 81.9 %). When the cut-off value was accepted as < 6 HU, transudates were differentiated from exudates with 97.2 % specificity. Conclusion: The attenuation measurements of pleural fluids can be considered as an efficacious way of differentiating exudative and transudative pleural effusions.

Source

Clinics

Volume

79

URI

https://doi.org/10.1016/j.clinsp.2024.100463
https://hdl.handle.net/11436/9275

Collections

  • PubMed İndeksli Yayınlar Koleksiyonu [2443]
  • Scopus İndeksli Yayınlar Koleksiyonu [5990]
  • TF, Dahili Tıp Bilimleri Bölümü Koleksiyonu [1569]
  • WoS İndeksli Yayınlar Koleksiyonu [5260]



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Instruction | Guide | Contact |

DSpace@RTEÜ

by OpenAIRE
Advanced Search

sherpa/romeo

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution AuthorThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution Author

My Account

LoginRegister

Statistics

View Google Analytics Statistics

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Guide|| Instruction || Library || Recep Tayyip Erdoğan University || OAI-PMH ||

Recep Tayyip Erdoğan University, Rize, Turkey
If you find any errors in content, please contact:

Creative Commons License
Recep Tayyip Erdoğan University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@RTEÜ:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.