• Türkçe
    • English
  • English 
    • Türkçe
    • English
  • Login
View Item 
  •   RTEÜ
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • Scopus İndeksli Yayınlar Koleksiyonu
  • View Item
  •   RTEÜ
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • Scopus İndeksli Yayınlar Koleksiyonu
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Frequency regulation of PV-reheat thermal power system via a novel hybrid educational competition optimizer with pattern search and cascaded PDN-PI controller

View/Open

Tam Metin / Full Text (1.942Mb)

Access

info:eu-repo/semantics/closedAccess

Date

2024

Author

Ekinci, Serdar
Izci, Davut
Can, Özay
Bajaj, Mohit
Blazek, Vojtech

Metadata

Show full item record

Citation

Ekinci, S., Izci, D., Can, O., Bajaj, M., & Blazek, V. (2024). Frequency regulation of PV-reheat thermal power system via a novel hybrid educational competition optimizer with pattern search and cascaded PDN-PI controller. Results in Engineering, 24, 102958. https://doi.org/10.1016/j.rineng.2024.102958

Abstract

Maintaining a stable balance between generated power and load demand is a critical challenge in modern power systems, especially with the increasing integration of renewable energy sources like photovoltaic (PV) systems. This study introduces a novel hybrid educational competition optimizer with pattern search (hECO-PS) algorithm to optimally tune a cascaded proportional-derivative with filter and proportional-integral (PDN-PI) controller for load frequency control (LFC) in a two-area power system comprising a PV system and a reheat thermal power system. The proposed hECO-PS algorithm enhances both global exploration and local exploitation capabilities, resulting in superior convergence rates and solution accuracy. The controller's performance was evaluated under various scenarios, including a 10 % step load change and solar radiation variations, demonstrating significant improvements in frequency regulation. The hECO-PS tuned PDN-PI controller achieved a minimum integral of time-weighted absolute error (ITAE) value of 0.4464, outperforming conventional methods like the modified whale optimization algorithm and sea horse algorithm, which yielded ITAE values of 2.6198 and 0.8598, respectively. Furthermore, the proposed controller reduced settling time by up to 46 % and minimized overshoot by up to 40 %. These results confirm the efficacy of the proposed approach in enhancing system stability and reliability under dynamic operating conditions, suggesting it as a promising solution for LFC in modern power systems with high renewable energy penetration.

Source

Results in Engineering

Volume

24

URI

https://doi.org/10.1016/j.rineng.2024.102958
https://hdl.handle.net/11436/9566

Collections

  • Scopus İndeksli Yayınlar Koleksiyonu [6032]
  • Teknik Bilimler Meslek Yüksekokulu Koleksiyonu [202]
  • WoS İndeksli Yayınlar Koleksiyonu [5260]



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Instruction | Guide | Contact |

DSpace@RTEÜ

by OpenAIRE
Advanced Search

sherpa/romeo

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution AuthorThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution Author

My Account

LoginRegister

Statistics

View Google Analytics Statistics

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Guide|| Instruction || Library || Recep Tayyip Erdoğan University || OAI-PMH ||

Recep Tayyip Erdoğan University, Rize, Turkey
If you find any errors in content, please contact:

Creative Commons License
Recep Tayyip Erdoğan University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@RTEÜ:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.