Exergy, exergoenvironmental and exergoeconomic evaluation of a heat pump-integrated wall heating system

Thumbnail

View/Open

Full Text / Tam Metin (2.123Mb)

Access

info:eu-repo/semantics/closedAccess

Date

2016

Author

Akbulut, Uğur
Utlu, Zafer
Kincay, Olcay

Metadata

Show full item record

Citation

Akbulut, U., Utlu, Z., kincay, O. (2016). Exergy, exergoenvironmental and exergoeconomic evaluation of a heat pump-integrated wall heating system. Energy, 107, 502-522. https://doi.org/10.1016/j.energy.2016.04.050

Abstract

In this study, a vertical ground source heat pump wall heating system belonging to the Yildiz Renewable Energy House on the Davutpasa Campus of Yildiz Technical University was experimentally and theoretically studied. the examination included energy, exergy, exergoenvironmental and exergoeconomic analyses from 1 January 2013 to 30 March 2013 (i.e., the "Winter Session"). Data were collected and uploaded to a MySQL database. "The moments when the heat pump is activated" was detected and "Monthly Average Values" were analysed. Theoretical analyses were conducted for the Winter Session and correlated with the experimental results. This study includes exergetically, exergoeconomically, and exergoenvironmental evaluate a building and its heating system from the generation stage to the envelope of the building. the findings are based on applying a low exergy, exergoenvironmental and exergoeconomic analysis to investigate the system" performance. the energy and exergy efficiencies of the entire system were 67.36% and 27.40%, respectively, and the energy and exergy efficiencies of the wall heating system panels were 86.61% and 82.90%, respectively. the monthly average exergy-based environmental impact value was 0.212 mPts/s. the exergoeconomic factors changed from 74.97% to 75.77%. (C) 2016 Elsevier Ltd. All rights reserved.

Source

Energy

Volume

107

URI

https://doi.org/10.1016/j.energy.2016.04.050
https://hdl.handle.net/11436/2450

Collections

  • Makine Mühendisliği Bölümü Koleksiyonu [335]
  • WoS İndeksli Yayınlar Koleksiyonu [5260]



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Instruction | Guide | Contact |

DSpace@RTEÜ

by OpenAIRE
Advanced Search

sherpa/romeo

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution AuthorThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution Author

My Account

LoginRegister

Statistics

View Google Analytics Statistics

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Guide|| Instruction || Library || Recep Tayyip Erdoğan University || OAI-PMH ||

Recep Tayyip Erdoğan University, Rize, Turkey
If you find any errors in content, please contact:

Creative Commons License
Recep Tayyip Erdoğan University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@RTEÜ:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.