dc.contributor.author | Markal, Burak | |
dc.contributor.author | Kul, Beyzanur | |
dc.date.accessioned | 2023-08-15T07:37:30Z | |
dc.date.available | 2023-08-15T07:37:30Z | |
dc.date.issued | 2023 | en_US |
dc.identifier.citation | Markal, B. & Kul, B. (2023). Influence of downstream cross-sectional area ratio on flow boiling characteristics of expanding micro pin fin heat sinks. International Communications in Heat and Mass Transfer, 143, 106689. https://doi.org/10.1016/j.icheatmasstransfer.2023.106689 | en_US |
dc.identifier.issn | 0735-1933 | |
dc.identifier.issn | 1879-0178 | |
dc.identifier.uri | https://doi.org/10.1016/j.icheatmasstransfer.2023.106689 | |
dc.identifier.uri | https://hdl.handle.net/11436/7997 | |
dc.description.abstract | In the present study, influence of downstream cross-sectional area ratio on flow boiling behavior of expanding micro-pin-fin heat sinks was experimentally studied. Three structured micro-pin-fin heat sinks, namely, Type1, Type2 and Type3 were used. Pure saturated conditions were taken into consideration in heat input interval of 90 W - 180 W. To show relation between mass flux and area ratio, two mass fluxes were considered (136 kg m- 2 s- 1 and 250 kg m- 2 s- 1). Outcomes showed that there was an optimum cross-sectional ratio maximizing thermal performance for expanding micro-pin-fin heat sinks. The advantage of prevention of bubble blockage was lost after a threshold expansion ratio due to dominant-compressible-vapor-based instabilities at the downstream region; and in this regard, mass flux played critical role due to liquid inertia force. For the given conditions, compared to uniformly distributed micro-pin-fin heat sink (Type1), expanding heat sinks (Type2 and Type3) led to increase in heat transfer coefficients up to, respectively, 498.9% and 216.5% at 250 kg m- 2 s- 1. Compared to Type1; Type2 and Type3 respectively decreased pressure drop up to 31.8% and 32.1% at 136 kg m- 2 s- 1. However, after heat input of 150 W, Type 3 experienced boiling crisis, and surface temperature jumped. | en_US |
dc.language.iso | eng | en_US |
dc.publisher | Elsevier | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Expansion ratio | en_US |
dc.subject | Micro-pin-fin | en_US |
dc.subject | Flow boiling | en_US |
dc.subject | Visualization | en_US |
dc.title | Influence of downstream cross-sectional area ratio on flow boiling characteristics of expanding micro pin fin heat sinks | en_US |
dc.type | article | en_US |
dc.contributor.department | RTEÜ, Mühendislik ve Mimarlık Fakültesi, Makine Mühendisliği Bölümü | en_US |
dc.contributor.institutionauthor | Markal, Burak | |
dc.contributor.institutionauthor | Kul, Beyzanur | |
dc.identifier.doi | 10.1016/j.icheatmasstransfer.2023.106689 | en_US |
dc.identifier.volume | 143 | en_US |
dc.identifier.startpage | 106689 | en_US |
dc.relation.journal | International Communications in Heat and Mass Transfer | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |