Basit öğe kaydını göster

dc.contributor.authorMarkal, Burak
dc.contributor.authorKul, Beyzanur
dc.date.accessioned2023-08-15T07:37:30Z
dc.date.available2023-08-15T07:37:30Z
dc.date.issued2023en_US
dc.identifier.citationMarkal, B. & Kul, B. (2023). Influence of downstream cross-sectional area ratio on flow boiling characteristics of expanding micro pin fin heat sinks. International Communications in Heat and Mass Transfer, 143, 106689. https://doi.org/10.1016/j.icheatmasstransfer.2023.106689en_US
dc.identifier.issn0735-1933
dc.identifier.issn1879-0178
dc.identifier.urihttps://doi.org/10.1016/j.icheatmasstransfer.2023.106689
dc.identifier.urihttps://hdl.handle.net/11436/7997
dc.description.abstractIn the present study, influence of downstream cross-sectional area ratio on flow boiling behavior of expanding micro-pin-fin heat sinks was experimentally studied. Three structured micro-pin-fin heat sinks, namely, Type1, Type2 and Type3 were used. Pure saturated conditions were taken into consideration in heat input interval of 90 W - 180 W. To show relation between mass flux and area ratio, two mass fluxes were considered (136 kg m- 2 s- 1 and 250 kg m- 2 s- 1). Outcomes showed that there was an optimum cross-sectional ratio maximizing thermal performance for expanding micro-pin-fin heat sinks. The advantage of prevention of bubble blockage was lost after a threshold expansion ratio due to dominant-compressible-vapor-based instabilities at the downstream region; and in this regard, mass flux played critical role due to liquid inertia force. For the given conditions, compared to uniformly distributed micro-pin-fin heat sink (Type1), expanding heat sinks (Type2 and Type3) led to increase in heat transfer coefficients up to, respectively, 498.9% and 216.5% at 250 kg m- 2 s- 1. Compared to Type1; Type2 and Type3 respectively decreased pressure drop up to 31.8% and 32.1% at 136 kg m- 2 s- 1. However, after heat input of 150 W, Type 3 experienced boiling crisis, and surface temperature jumped.en_US
dc.language.isoengen_US
dc.publisherElsevieren_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectExpansion ratioen_US
dc.subjectMicro-pin-finen_US
dc.subjectFlow boilingen_US
dc.subjectVisualizationen_US
dc.titleInfluence of downstream cross-sectional area ratio on flow boiling characteristics of expanding micro pin fin heat sinksen_US
dc.typearticleen_US
dc.contributor.departmentRTEÜ, Mühendislik ve Mimarlık Fakültesi, Makine Mühendisliği Bölümüen_US
dc.contributor.institutionauthorMarkal, Burak
dc.contributor.institutionauthorKul, Beyzanur
dc.identifier.doi10.1016/j.icheatmasstransfer.2023.106689en_US
dc.identifier.volume143en_US
dc.identifier.startpage106689en_US
dc.relation.journalInternational Communications in Heat and Mass Transferen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster