• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   RTEÜ
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • Scopus İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
  •   RTEÜ
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • Scopus İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Fire retardation, compressive strength and durability analysis of concrete reinforced with novel plasters: An experimental, computational and statistical research

Göster/Aç

Tam Metin / Full Text (15.32Mb)

Erişim

info:eu-repo/semantics/openAccess

Tarih

2024

Yazar

Ustabaş, İlker
Cüce, Pınar Mert
Alvur, Emre
Kesepara, Duygu
Yılmaz, Yusuf Nadir
Cüce, Erdem
Alshahrani, Saad

Üst veri

Tüm öğe kaydını göster

Künye

Ustabaş, İ., Cüce, P.M., Alvur, E., Kesepara, D. & Yılmaz, Y.N., Cüce, E. & Alshahrani, S. (2024). Fire retardation, compressive strength and durability analysis of concrete reinforced with novel plasters: An experimental, computational and statistical research. Case Studies in Thermal Engineering, 55, 104156. https://doi.org/10.1016/j.csite.2024.104156

Özet

Concrete is an essential component of the construction industry, valued for its high compressive strength (CS) and durability. However, when exposed to extreme conditions like fire without protective structural elements, its physical integrity deteriorates rapidly, leading to significant alterations in its mechanical properties. This research aims to provide a potential solution to this issue by assessing the fire resistance of various concrete samples, including unplastered (UNP), roughly plastered (RP), and those with contemporary insulation plaster (CIP) substitutions, at different thicknesses. These samples are subjected to varying temperatures and exposure times within an oven, followed by CS testing. These temperature levels and time intervals correspond to 300 °C, 450 °C, and 600 °C, with the time range is restricted to 60, 90, and 120-min, respectively. The results indicate that an increase in sample thickness correlates with a reduction in concrete degradation at high temperatures. Moreover, the findings reveal that after 120-min of exposure at 600 °C, UNP, RP, and CIP-reinforced samples achieve CSs of 27.435 MPa, 27.74 MPa, and 30.28 MPa, respectively. Notably, the 3 cm CIP-reinforced sample exhibits a CS exceeding 30 MPa under the most extreme conditions. The research incorporates regression and computational fluid dynamics (CFD) analyses to complement the experimental investigation. The regression analysis suggests that CIP-reinforced samples can withstand temperatures up to 600 °C for approximately 173-min, while the study implies that they could endure temperatures as high as 861 °C during a 120-min exposure.

Kaynak

Case Studies in Thermal Engineering

Cilt

55

Bağlantı

https://doi.org/10.1016/j.csite.2024.104156
https://hdl.handle.net/11436/8866

Koleksiyonlar

  • İnşaat Mühendisliği Bölümü Koleksiyonu [260]
  • Makine Mühendisliği Bölümü Koleksiyonu [329]
  • Mimarlık Bölümü Koleksiyonu [82]
  • Scopus İndeksli Yayınlar Koleksiyonu [5931]
  • WoS İndeksli Yayınlar Koleksiyonu [5260]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Yönerge | Rehber | İletişim |

DSpace@RTEÜ

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

İstatistikler

Google Analitik İstatistiklerini Görüntüle

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Rehber|| Yönerge || Kütüphane || Recep Tayyip Erdoğan Üniversitesi || OAI-PMH ||

Recep Tayyip Erdoğan Üniversitesi, Rize, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Recep Tayyip Erdoğan Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@RTEÜ:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.