ANN and CFD driven research on main performance characteristics of solar chimney power plants: Impact of chimney and collector angle

Göster/Aç

Tam Metin / Full Text (6.208Mb)

Erişim

info:eu-repo/semantics/openAccess

Tarih

2024

Yazar

Cüce, Pınar Mert
Cüce, Erdem
Mandal, Dipak Kumar
Gayen, Dilip Kumar
Asif, Muhammad
Bouabidi, Abdallah
Alshahrani, Saad
Prakash, Chander
Soudagar, Manzoore Elahi M.

Üst veri

Tüm öğe kaydını göster

Künye

Cuce, P. M., Cuce, E., Mandal, D. K., Gayen, D. K., Asif, M., Bouabidi, A., Alshahrani, S., Prakash, C., & Soudagar, M. E. M. (2024). ANN and CFD driven research on main performance characteristics of solar chimney power plants: Impact of chimney and collector angle. Case Studies in Thermal Engineering, 104568. https://doi.org/10.1016/j.csite.2024.104568

Özet

Solar energy systems operate directly connected to the sun. Solar chimney power plants are privileged systems that can provide power output even in cloudy weather and during hours when there is no sun. The design and sizing of this system, which researchers focused on after its first application in the 1980s, is very effective on its performance. In this study, the collector slope and chimney slope that give maximum power output for the Manzanares pilot plant are investigated with a 3D CFD model. Simulations made using the RNG k-e turbulence model and the DO (discrete ordinates) solar ray tracing algorithm provide results that are in high compatibility with experimental data and literature. It is understood that the system provides maximum power at 0.6° collector slope and 1.5° chimney divergence angle. It is seen that the system, which gives a power output of approximately 46 kW in the reference case, exceeds the power output by 4.5 times and reaches 216.853 kW in the design that includes the collector and chimney slope. The effects of the main elements of the system on the performance are also included by changing the collector radius and chimney height while preserving these inclination angles. More than the power output in the reference case, 49.233 kW, can be achieved with the inclined design, with a collector radius of 73.2 m and a chimney height of 155.68 m. Although the effect of increasing the chimney height on power output continues after 1.2 floors, its effect decreases. In the study, it is seen that increasing the chimney height and changing the collector radius provide a greater increase in power output. Furthermore, the scope extends to the incorporation of an Artificial Neural Network (ANN) model, presenting a novel approach to predicting SCPP system performance. The findings ascertain the utilisation of 9 neurons in the hidden layer of the ANN, demonstrating a precise alignment with the study data.

Kaynak

Case Studies in Thermal Engineering

Cilt

60

Bağlantı

https://doi.org/10.1016/j.csite.2024.104568
https://hdl.handle.net/11436/9101

Koleksiyonlar

  • Makine Mühendisliği Bölümü Koleksiyonu [329]
  • Mimarlık Bölümü Koleksiyonu [82]
  • Scopus İndeksli Yayınlar Koleksiyonu [5931]
  • WoS İndeksli Yayınlar Koleksiyonu [5260]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Yönerge | Rehber | İletişim |

DSpace@RTEÜ

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

İstatistikler

Google Analitik İstatistiklerini Görüntüle

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Rehber|| Yönerge || Kütüphane || Recep Tayyip Erdoğan Üniversitesi || OAI-PMH ||

Recep Tayyip Erdoğan Üniversitesi, Rize, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Recep Tayyip Erdoğan Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@RTEÜ:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.