Basit öğe kaydını göster

dc.contributor.authorCüce, Pınar Mert
dc.contributor.authorCüce, Erdem
dc.contributor.authorAlvur, Emre
dc.date.accessioned2024-09-25T10:41:35Z
dc.date.available2024-09-25T10:41:35Z
dc.date.issued2023en_US
dc.identifier.citationMERT CÜCE, A. P., CÜCE, E., & ALVUR, E. (2024). Internal Or External Thermal Superinsulation Towards Low/Zero Carbon Buildings? A Critical Report. Gazi Journal of Engineering Sciences, 9(3), 435–442. https://doi.org/10.30855/gmbd.07050777en_US
dc.identifier.issn2149-9373
dc.identifier.urihttps://doi.org/10.30855/gmbd.07050777
dc.identifier.urihttps://hdl.handle.net/11436/9404
dc.description.abstractThe effort to create low-carbon societies is now more than just a need for a sustainable world. According to the sectoral energy analyses carried out to reduce world energy consumption figures and greenhouse gas emissions, buildings are one of the most striking potential measures within the net zero target of the International Energy Agency (IEA) by 2050. Low/zero carbon standards are developed in this regard, which basically propose low-emission design and operational performance for buildings. Rather than using conventional insulation materials and techniques, drastic measures like thermal superinsulation are required to meet these standards in buildings. Among thermal superinsulation materials, aerogel blankets (ABs) and vacuum insulation panels (VIPs) attract attention day after day owing to their very low thermal conductivity ranges. Despite the slim, lightweight, and highly thermally resistive features of building envelopes retrofitted with ABs and VIPs, there are still some challenges, such as thermal bridges, hot and cold spots, durability, and especially cost issues. The aforesaid challenges usually take place when a wrong decision is made to internal or external insulation. There are still numerous discrepancies in the pros and cons of internal and external thermal superinsulation retrofit. Therefore, this short communication deals with the said discussion through the in-situ performance findings of retrofitted buildings.en_US
dc.language.isoengen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectInternal or external insulationen_US
dc.subjectThermal superinsulationen_US
dc.subjectThermal bridgesen_US
dc.subjectAerogel blanketen_US
dc.subjectVacuum insulation panelen_US
dc.titleInternal or external thermal superinsulation towards low/zero carbon buildings? A critical reporten_US
dc.title.alternativeDüşük/sıfır karbonlu binalara yönelik i̇ç veya dış ısı yalıtımı? Kritik bir raporen_US
dc.typearticleen_US
dc.contributor.departmentRTEÜ, Mühendislik ve Mimarlık Fakültesi, Mimarlık Bölümüen_US
dc.contributor.institutionauthorCüce, Pınar Mert
dc.contributor.institutionauthorCüce, Erdem
dc.contributor.institutionauthorAlvur, Emre
dc.identifier.doi10.30855/gmbd.07050777en_US
dc.identifier.volume9en_US
dc.identifier.issue3en_US
dc.identifier.startpage435en_US
dc.identifier.endpage442en_US
dc.relation.journalGazi Mühendislik Bilimleri Dergisien_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster