Basit öğe kaydını göster

dc.contributor.authorGürbüz, Ali
dc.contributor.authorKayıkçı, Furkan Yurdakul
dc.date.accessioned2025-01-20T08:26:31Z
dc.date.available2025-01-20T08:26:31Z
dc.date.issued2024en_US
dc.identifier.citationGürbüz, A., & Kayıkçı, F. Y. (2024). Yapı-zemin Etkileşimini Dikkate Alan Analizlerde Sismik Taban İzolatörünün Etkisi. Türk Deprem Araştırma Dergisi, 6(2), 271-285. https://doi.org/10.46464/tdad.1383585en_US
dc.identifier.issn2687-301X
dc.identifier.urihttps://doi.org/10.46464/tdad.1383585
dc.identifier.urihttps://hdl.handle.net/11436/9927
dc.description.abstractThe aim of this study is to investigate the effect of the analysis technique that considers the soil-structure interaction in buildings with seismic base isolators. Taking the soil-structure interaction into consideration, especially in the analysis of buildings sitting on soft soils, provides more precise results. However, in structures where seismic base isolators are used, this benefit decreases as the vibrations in the ground affect the structure by being damped. The effect of considering the soil-structure interaction in such buildings on the results is still an issue that needs to be investigated. For this purpose, within the scope of the study; a 7-storey sample building plan with suitable features for the use of base isolators was selected. Four different models were created for the selected structure. In the first two models, a structure without a base isolator was built into the ground and then modelled with the ground. In the next two models, the seismic base isolator is included in the solution. Dynamic time-history analysis was applied to all created models for 11 different earthquake records. As a result of the analyses, the changes in the reactions such as accelerations, shear forces and drifts acting on the structure were examined in fixed model and in the model with 3D soil. In case of non-base isolated structure, resulting responses are fairly big while in case of base isolated structure, it is seen that resulting responses of the structure are small.en_US
dc.language.isoturen_US
dc.publisherAfet ve Acil Durum Yonetimi Baskanligi (AFAD)en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectSeismic base isolatoren_US
dc.subjectSoil-structure interactionen_US
dc.subjectTime history analysisen_US
dc.titleZemin-yapı etkileşimini dikkate alan analizlerde sismik taban i̇zolatörünün etkisien_US
dc.title.alternativeThe effect of seismic base isolator in analysis considering soil-structure interactionen_US
dc.typearticleen_US
dc.contributor.departmentRTEÜ, Mühendislik ve Mimarlık Fakültesi, İnşaat Mühendisliği Bölümüen_US
dc.contributor.institutionauthorGürbüz, Ali
dc.contributor.institutionauthorKayıkçı, Furkan Yurdakul
dc.identifier.doi10.46464/tdad.1383585en_US
dc.identifier.volume6en_US
dc.identifier.issue2en_US
dc.identifier.startpage271en_US
dc.identifier.endpage285en_US
dc.relation.journalTurk Deprem Arastirma Dergisien_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster