• Türkçe
    • English
  • English 
    • Türkçe
    • English
  • Login
View Item 
  •   RTEÜ
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • View Item
  •   RTEÜ
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Performance assessment of solar chimney power plants with the impacts of divergent and convergent chimney geometry

Thumbnail

View/Open

cüce-2021.pdf (2.117Mb)

Access

info:eu-repo/semantics/openAccess

Date

2021

Author

Cüce, Erdem
Saxena, Abhishek
Cüce, Pınar Mert
Şen, Harun
Guo, Shaopeng
Sudhakar, K.

Metadata

Show full item record

Citation

Cuce, E., Saxena, A., Cuce, M.P., Sen, H., Guo, S. & Sudhakar, K. (2021). Performance assessment of solar chimney power plants with the impacts of divergent and convergent chimney geometry. International journal of Low-Carbon Technologies, 16(3), 704-714. https://doi.org/10.1093/ijlct/ctaa097

Abstract

Influence of area ratio (AR) on main performance parameters of solar chimney power plants (SCPPs) is investigated through a justified 3D axisymmetric CFD model. Geometric characteristics of Manzanares pilot plant (MPP) are taken into consideration for the numerical model. AR is varied from 0.5 to 10 to cover both concave and convex (convergent and divergent) solar chimney designs. Following the accuracy verification of the CFD results and proving mesh-independent solution, main performance oriented parameters are assessed as a function of AR such as velocity, temperature and pressure distribution within MPP, temperature rise of air in collector, mass flow rate of air around the turbine area, dynamic pressure difference across the turbine, minimum static pressure in the entire plant, power output and system efficiency. The results reveal that AR plays a vital role in performance figures of MPP. Mass flow rate of air (<(m)over dot>) is found to be 1122.1 kg/s for the reference geometry (AR = 1), whereas it is 1629.1 kg/s for the optimum AR value of 4. System efficiency (eta) is determined to be 0.29% for the reference case; however, it is enhanced to 0.83% for the AR of 4.1. MPP can generate 54.3 kW electrical power in its current design while it is possible to improve this figure to 168.5 kW with the optimal AR value.

Source

International journal of Low-Carbon Technologies

Volume

16

Issue

3

URI

https://doi.org/10.1093/ijlct/ctaa097
https://hdl.handle.net/11436/6358

Collections

  • Makine Mühendisliği Bölümü Koleksiyonu [337]
  • Mimarlık Bölümü Koleksiyonu [84]
  • Scopus İndeksli Yayınlar Koleksiyonu [6023]
  • WoS İndeksli Yayınlar Koleksiyonu [5260]

Related items

Showing items related by title, author, creator and subject.

  • Numerical performance modelling of solar chimney power plants: Influence of chimney height for a pilot plant in Manzanares, Spain 

    Cüce, Erdem; Şen, Harun; Cüce, Pınar Mert (Elsevier, 2020)
    3D axisymmetric CFD model is developed for a solar chimney power plant (SCPP) in Manzanares, Spain, and potential impacts of chimney height (H) on main performance parameters are comprehensively analysed. Mesh-independent ...
  • ANN and CFD driven research on main performance characteristics of solar chimney power plants: Impact of chimney and collector angle 

    Cüce, Pınar Mert; Cüce, Erdem; Mandal, Dipak Kumar; Gayen, Dilip Kumar; Asif, Muhammad; Bouabidi, Abdallah; Alshahrani, Saad; Prakash, Chander; Soudagar, Manzoore Elahi M. (Elsevier, 2024)
    Solar energy systems operate directly connected to the sun. Solar chimney power plants are privileged systems that can provide power output even in cloudy weather and during hours when there is no sun. The design and sizing ...
  • Divergent chimney and sloping collector design for ground heat source integrated solar chimney power plants 

    Cüce, Erdem (Springer, 2024)
    With energy resources being fossil fuel-based, increasing energy production has already reached levels that threaten human health. In this situation, the use of alternative energy sources is seen as the only solution. Solar ...



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Instruction | Guide | Contact |

DSpace@RTEÜ

by OpenAIRE
Advanced Search

sherpa/romeo

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution AuthorThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution Author

My Account

LoginRegister

Statistics

View Google Analytics Statistics

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Guide|| Instruction || Library || Recep Tayyip Erdoğan University || OAI-PMH ||

Recep Tayyip Erdoğan University, Rize, Turkey
If you find any errors in content, please contact:

Creative Commons License
Recep Tayyip Erdoğan University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@RTEÜ:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.