Assessment of the thermo-hydraulic efficiency of an indoor-designed jet impingement solar thermal collector roughened with single discrete arc-shaped ribs

Thumbnail

Göster/Aç

Full Text / Tam Metin (6.658Mb)

Erişim

info:eu-repo/semantics/openAccess

Tarih

2022

Yazar

Kumar, Raj
Cüce, Erdem
Kumar, Sushi
Thapa, Sashank
Gupta, Paras
Goel, Bhaskar
Saleel, C. Ahamed
Shaik, Saboor

Üst veri

Tüm öğe kaydını göster

Künye

Kumar, R., Cuce, E., Kumar, S.,Thapa, S., Gupta, P., Goel, B., Saleel, C.A. & Shaik, S. (2022). Assessment of the Thermo-Hydraulic Efficiency of an Indoor-Designed Jet Impingement Solar Thermal Collector Roughened with Single Discrete Arc-Shaped Ribs. Sustainability, 14(6), 3527. https://doi.org/10.3390/su14063527

Özet

This study illustrates the impact of single discrete arc-shaped ribs (SDASR)-type artificial roughness on the performance of a jet impingement solar thermal collector (JISTC). The impact of parametric variations of SDASR on the Nusselt number (Nu(sdr)), friction factor (f(sdr)), and thermohydraulic performance (eta(sdr)) is examined. The spacer length (S-sdr) of the SDASR was changed from 0 mm to 300 mm in stages of 100 mm during the experiment. The fixed parameters of the SDASR were a relative discrete distance (D-d/L-v) of 0.67, relative discrete width (g(w)/H-r) of 0.87, relative rib height (H-r/H) of 0.047, relative rib pitch (P-r/H) of 1.7, angle of an arc (alpha(sdr)) of 60 degrees, jet diameter ratio (D-j/D-hy) of 0.065, streamwise pitch ratio (X/D-hy) of 1.72, and spanwise pitch ratio (Y/D-hy) of 0.82. The Reynolds number (Re) was altered from 3000 to 19,000. The Nu(sdr) and f(sdr) of a JISTC with a roughened absorber plate was found to be enhanced by 5.25 and 5.98 times as compared to an STC without artificial roughness. The optimal findings of Nu(sdr), f(sdr), and eta(sdr) were achieved at S-sdr = 0 mm. The maximum value of the eta(sdr) obtained at S-sdr = 0 mm was 2.9.

Kaynak

Sustainability

Cilt

14

Sayı

+

Bağlantı

https://doi.org/10.3390/su14063527
https://hdl.handle.net/11436/7061

Koleksiyonlar

  • Makine Mühendisliği Bölümü Koleksiyonu [329]
  • Scopus İndeksli Yayınlar Koleksiyonu [5931]
  • WoS İndeksli Yayınlar Koleksiyonu [5260]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Yönerge | Rehber | İletişim |

DSpace@RTEÜ

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

İstatistikler

Google Analitik İstatistiklerini Görüntüle

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Rehber|| Yönerge || Kütüphane || Recep Tayyip Erdoğan Üniversitesi || OAI-PMH ||

Recep Tayyip Erdoğan Üniversitesi, Rize, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Recep Tayyip Erdoğan Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@RTEÜ:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.